Accuracy:
AC or DC power: ±1% of measured value ±0.006 ft/s (± 0.0018 m/s)
Battery power: ±1% of measured value ±0.006 ft/s (± 0.0018 m/s)
Reverse Flow: ±1% of measured value ±0.006 ft/s (± 0.0018 m/s)
IMPORTANT NOTICE ON FLOW METER ACCURACY: The flow meter, the cable and the electronics are factory calibrated for accuracy as a single unit. Changing the cable length with the Splice Kit changes the accuracy of the meter and invalidates the calibration certificate.
Multiple point wet flow calibration of every complete flow tube with its signal converter. If desired, the tests can be witnessed by the customer. The McCrometer test facilities are traceable to the National Institute of Standards & Technology. Uncertainty relative to flow is ±0.15%.
Certifications 2:
Standard model:
- ISO 9001:2015 certified quality management system
- NSF/ANSI/CAN 61 & NSF/ANSI 372
- Certified by MET to UL 61010-1
HL model:
- ISO 9001:2015 certified quality management system
- NSF/ANSI/CAN 61 & NSF/ANSI 372
- Certified to NSF / ANSI Standards*
- Certified by MET to UL 61010-1 and MET C22.2 No. 61010-1-04
- - Class I, Division 2, Groups A-D, T5
- - Class I, Zone 2, IIC T5
Conductivity:
5 µs/cm
Converter:
ProComm 3000 series (ProComm GO)
May be either meter mount or remote mount
Directional Response:
Forward and reverse flow indication and forward, reverse, net totalization are standard with all meters
Electrical Connections:
Compression gland seals
Quick-Connect
Electrode:
Type 316 stainless steel, Hastelloy optional
IP Rating:
Quick Connect: (NEMA 6P/IP68 with remote converter)
Compression gland seals: (NEMA 6P/IP68 with remote converter)
Liner:
135 epoxy Ultraliner
Line size:
Grooved end: 4:” - 12”
Flanged end: 4:” - 12”
Material:
Carbon steel, stainless steel, epoxy liner
Measurement Method:
Electromagnetic flow based on Faraday’s law
Options:
- DC powered converter (10-35 VDC, 21 W)
- Meter mounted converter
- Extended warranty
- ANSI or AWWA flanges
- Special lay lengths, including ISO standard lay lengths
- Quick connect cable fittings
- Converter sun shield
- Battery or battery-solar powered converter
Outputs:
- Modbus
- HART
- Smart Output™ (Sensus, Itron 6, Itron 9)
- Datalogger
- Built-in verification
Pressure Rating:
150 PSI maximum working pressure
300 PSI maximum working pressure
Repeatability:
±0.05% or ±.0008ft/s (±0.25mm/s), whichever is greater
Requirements:
Pipe Run Requirements
- 2” & 3” wafer style: 3D upstream / 1D downstream
- 4” and larger flanged: 1D upstream / 0D downstream
Sensor Cable:
Standard: 25’/7.6 m McCrometer supplied submersible cable with each remote mount unit.
Optional: Up to 500’/152.4 m, or 25’/7.6 m max for battery powered.
Quick Connect: Available in standard cable lengths:
Feet: 25, 50, 75, 100, 125, 150, 175, 200, 500
Meters: 7.6, 15.25. 22.5, 30.5, 38.1, 45.75, 53.3, 61, 152.4
Custom cable lengths at additional cost.
Sensor Immersion Depth:
With standard strain relief cable: 9 m (30 ft.)
With optional quick connect cable: 1.8 m (6 ft.)
Temperature:
Operating Temperature: -10 to 60°C (14 to 140°F)
Storage Temperature: -15 to 60°C (5 to 140° F)
Velocity Measurement Range:
0.2 to 32 FPS
Warranty:
24 months