Altitude:
Operating: 2000 m
Storage: 12,000 m
Battery Life:
Five-year expected battery life, five-year battery warranty
Connections:
Optional shielded cable for 10 - 32 VDC/4-20 mA output
Optional shielded cable for pulse out
Data Logger:
Standard with all models, minimum of five years of data stored
Display:
• 2-Line LCD display (no backlight)
• Non-volatile memory
• Anti-reverse totalizer (standard)
• Total (to 9 digits of precision)
• Flow rate and velocity (to 5 digits of precision)
• Two alarms: low battery and empty pipe (optional)
• Opening lid activates display
Digits: 5 Rate, 9 Total
Electrical Certifications:
IEC 61010-1, Pollution Degree II
Overvoltage protection Category III
Housing Details:
Diecast aluminum, powder coated enclosure w/ tamper resistant seal, 6½” x 6½” x 43/8” tall
Indoor/Outdoor:
Indoor or outdoor use
IP Rating:
IP67 Die cast aluminum converter
Operating Temperature Range:
4° to 140° F (-20° to 60° C)
Options:
Data Logger - included as standard with five years of data storage at default (12 hr) interval. (Cable sold separately)
AC, DC, and battery powered with battery backup powered available
Outputs:
Digital output:
Digital pulse (open collector) output for volumetric
• Two isolated digital pulse (open collector) outputs for volumetric
• AMI output
Analog Output:
4 - 20 mA: Galvanically Isolated, 16 Bit resolution. All power configurations (including battery). Note: 9-30 VDC loop power required (not supplied via converter)
Power:
Battery: Standard: three 3.6V lithium-thionyl chloride (Li-SOCI2) D size batteries with two AA backup batteries
AC Power: 100 - 240 VAC/45-66Hz (4W)
DC Power: Linear power supply 10 - 35VDC (4 W)
Relative Humidity:
0% to 100%
Standard storage temperature:
-4° to 140° F (-20° to 60° C)